Al hacer clic en el botón de una pregunta.
Weight wire rope capacity chart pdf.
See page 91 for reduced choker capacity when using these hook sizes.
Multiply the load factor times the minimum weight to be supported by the leg i e.
1000 pounds times 1 154 1154 pounds.
Coated wire rope wire ropes coated with a film of thermoplastic resin such as nylon and polyethylene as thin as 0 02mm manufactured by continuous extrusion molding.
4 steel wire rope 6 strand 4 steel wire rope 6 strand 6 x 19 fc according en 12385 4 nominal diameter weight 100 m minimum breaking load 1 770 n mm2 minimum breaking load 1 960 n mm2 mm kg kn kg kn kg 3 3 11 4 89 500 5 42 550 4 5 54 8 69 890 9 63 980 5 8 65 13 60 1 390 15 00 1 530 6 12 50 19 60 2 000 21 70 2 210.
Nominal strength in pounds.
If you are using two wire rope slings in a vertical hitch called a 2 legged bridle hitch in a straight.
The rated sling capacity needed is then 2308 1154 2 pounds in basket capacity to safely lift the 2000 pound load.
Wire rope chart 6x37 6x19 iwrc eips rope.
Wire rope includes standard products such as wire ropes composed of strand s of ø0 03mm wires as well as special wire ropes composed of strand s of ø0 013mm ultra fine wires.
Length tolerances single part wire rope slings standard length tolerance is plus or minus two rope diameters or plus or minus 0 5 of the sling length whichever is greater.
Working load limit chart.
Wire to most wire rope users 6 x 19 means 6 x 25 filler wire.
Assume that the leg angle will be 60.
Durante la prueba puede hacer clic en el botón revisar pregunta para marcar la pregunta en amarillo como un recordatorio visual para volver a visitar la pregunta antes de enviar las respuestas de la prueba.
Splicing winding services magnetic particle inspection water weight proof load testing.
Suerte en el test.
In general we recommend the use of a 6 x 26ws in any application where a 6 x 25f is used.
Hitch wll in vert.
The weight of the lift while a critical component is only a part of the information.
Nominal strength in metric tons.
The load factor for 60 from the load factor chart is 1 154.
Wire rope sling selection rated capacities design factors and d d ratios.
Working load limit under general use with 1770 grade wire and wire rope core with ferrule secured eyes.
Recommended safe working load a 5 1 design factor lbs.
Single part body hand spliced wire rope slings rated capacity tons e e basket eye e ht e eh hitch dimensions thimble hook rope choker dia.
Nominal strength in short tons.
No se preocupe el test no está medido en tiempo así que relájese y concéntrese en las preguntas y lo hará genial.
Nominal strength in kg.